Evidence for superior efficacy and safety of LASIK over photorefractive keratectomy for correction of myopia.

Ophthalmology. 2006 Nov;113(11):1897-908.

Moorfields Eye Hospital, London, United Kingdom. a.shortt@ucl.ac.uk

PURPOSE: To examine possible differences in efficacy and safety between LASIK and photorefractive keratectomy (PRK) for correction of myopia. DESIGN: Meta-analysis/systematic review. PARTICIPANTS: Patient data from previously reported prospective randomized controlled trials (PRCTs) and a systematic review of prospective case series in the Food and Drug Administration (FDA) clinical trials database. METHODS: A comprehensive literature search was performed using the Cochrane Collaboration methodology to identify PRCTs comparing LASIK and PRK for correction of myopia. A meta-analysis was performed on the results of PRCTs. In parallel, a systematic review of prospective data from FDA case series of LASIK and PRK for correction of myopia was undertaken. MAIN OUTCOME MEASURES: Key efficacy outcomes (uncorrected visual acuity [UCVA] > or = 20/20, +/-0.50 diopters [D] of the target mean refractive spherical equivalent) and safety outcomes (loss of > or =2 lines of best spectacle-corrected visual acuity [BSCVA], final BSCVA > or = 20/40, and final BSCVA <> or =20/20). RESULTS: Seven PRCTs were identified comparing PRK (683 eyes) and LASIK (403 eyes) for correction of myopia. More LASIK patients achieved UCVA > or = 20/20 at 6 months (odds ratio, random effects model [95% confidence interval], 1.72 [1.14-2.58]; P = 0.009) and 12 months (1.78 [1.15-2.75], P = 0.01). Loss of > or =2 lines of BSCVA at 6 months was less frequent with LASIK (2.69 [1.01-7.18], P = 0.05). Data from 14 LASIK (7810 eyes) and 10 PRK (4414 eyes) FDA laser approval case series showed that more LASIK patients achieved UCVA of 20/20 or better at 12 months (1.15 [1.03-1.29], P = 0.01), significantly more LASIK patients were within +/-0.50 D of target refraction at 6 months (1.38 [1.26-1.50], P<0.00001) p =" 0.0009)"> or =2 lines of BSCVA at 6 months was less frequent with LASIK (2.91 [2.22-3.83], P<0.00001).> or =5 years ago. It is therefore unclear how our findings relate to present-day methods and outcomes. Further trials comparing contemporary equipment and techniques are needed to reevaluate the relative merits of these procedures.

PMID: 17074559 [PubMed - indexed for MEDLINE]

1 comment:

Unknown said...

The technology has advanced since the survey, it should be redone!